  • Ultra Split-R32 Split Heat Pump-VISSPLUS
  • Ultra Split-R32 Split Heat Pump-VISSPLUS 18KW,24KW
  • Ultra Split-R32 Split Heat Pump-VISSPLUS
  • Ultra Split-R32 Split Heat Pump-VISSPLUS 18KW,24KW

UltraHeat Split Series
Split Heat Pump filled with R32 refrigerant

Refrigerant: R32
Power: 220-240V/50HZ
Type of Components Full DC Inverter
Capacity Availability: 6-24kw,mono and triple phase
ErP Class: A+++(35°C),A++(35°C)
Max.Water Temperature: 65°C
Type Outdoor Unit +Indoor Unit
Operating Ambient Temperature: -30~43°C

Application and Functions

UltraHeat series is a type of air source heat pump with two packages-outdoor unit and indoor unit.As a heat pump manufacturer,VISSPLUS developed it by a wide range heating capacity from 6kw to 24kw,which is targeted for the resdential house mainly.It provide hot water to the radiators and floor loops to warm the room in winter and cold water to the fan coils to cool the rooms in summer.One Ultraheat single heat pump unit could be suitable for heating the house space from 80m2 to 300m2.

heating and cooling of ultraheat heat pump

Collections

photos of UltraHeat R32 split type,6.5kw
  • Mono Power Phase
  • 6.5kW Rated Heating Capacity(A7C/W35C)
  • R32 Filled Refrigerant
  • A+++/A++
photos of UltraHeat R32 split type,10.5kw
  • Mono Power Phase
  • 10.5kW Rated Heating Capacity(A7C/W35C)
  • R32 Filled Refrigerant
  • A+++/A++
photos of UltraHeat R32 split type14.5kw
  • Mono Power Phase
  • 14.5kW Rated Heating Capacity(A7C/W35C)
  • R32 Filled Refrigerant
  • A+++/A++
photos of UltraHeat R32 split type,18.5kw
  • Mono Power Phase
  • 18.5kW Rated Heating Capacity(A7C/W35C)
  • R32 Filled Refrigerant
  • A+++/A++
photos of UltraHeat R32 split type14.5kw
  • Triple Power Phase
  • 10.5kW Rated Heating Capacity(A7C/W35C)
  • R32 Filled Refrigerant
  • A+++/A++
photos of UltraHeat R32 split type14.5kw
  • Triple Power Phase
  • 14.5kW Rated Heating Capacity(A7C/W35C)
  • R32 Filled Refrigerant
  • A+++/A++
photos of UltraHeat R32 split type,18.5kw
  • Triple Power Phase
  • 18.5kW Rated Heating Capacity(A7C/W35C)
  • R32 Filled Refrigerant
  • A+++/A++
photos of UltraHeat R32 split type,24kw
  • Triple Power Phase
  • 24kW Rated Heating Capacity(A7C/W35C)
  • R32 Filled Refrigerant
  • A+++/A++
VISSPLUS Factory Model VR3HP-065INV-S VR3HP-105INV-S VR3HP-145INV-S VR3HP-185INV-S VR3HP-105INV-ST VR3HP-145INV-ST VR3HP-185INV-ST VR3HP-240INV-ST
Power Supply 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 380-415/1/50 380-415/1/50 380-415/1/50 380-415/1/50
Mono Phase Mono Phase Mono Phase Mono Phase Triple Phase Triple Phase Triple Phase Triple Phase
Rated Heating Capacity(A7/W35) 6.5 10.6 14.8 18.5 10.6 14.8 18.5 23.95
Performance Data
Energy efficiency class 35C / A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Energy efficiency class 55C / A++ A++ A++ A++ A++ A++ A++ A++
Heating Capacity A-7/W35 kW 2.10-6.19 3.53-9.10 4.45-12.30 5.21-15.28 3.53-9.10 4.45-12.30 5.21-15.28 6.13-19.46
Power Consumption kW 0.64-2.22 0.97-3.32 1.30-4.79 1.54-6.09 0.97-3.32 1.30-4.79 1.54-6.09 1.86-7.44
Heating Capacity Rated kW 4.82 7.89 11.00 13.99 7.89 11.00 13.99 17.88
COP w/w 3.19 2.98 2.97 2.91 2.98 2.97 2.91 2.80
Heating Capacity A2/W35 kW 2.36-7.22 3.96-10.61 5.00-14.35 5.85-17.83 3.96-10.61 5.00-14.35 5.85-17.83 6.89-22.70
Power Consumption kW 0.59-2.00 0.90-3.00 1.20-4.32 1.42-5.50 0.90-3.00 1.20-4.32 1.42-5.50 1.72-6.72
Heating Capacity Rated kW 5.62 9.2 12.83 16.32 9.2 12.83 16.32 20.85
COP w/w 4.12 3.86 3.84 3.76 3.86 3.84 3.76 3.62
Heating Capacity A7/W35 kW 2.50-8.30 4.20-12.20 5.30-16.50 6.20-20.50 4.20-12.20 5.30-16.60 6.20-20.50 6.50-26.10
Power Consumption kW 0.57-1.92 0.86-2.88 1.15-4.15 1.36-5.28 0.86-2.88 1.15-4.15 1.36-5.28 1.78-6.45
Heating Capacity Rated kW 6.46 10.58 14.75 18.77 10.58 14.75 18.77 23.98
COP w/w 4.93 4.62 4.60 4.51 4.62 4.60 4.51 4.34
Heating Capacity A-7/W55 kW 1.93-5.68 3.23-8.35 4.11-11.26 5.29-14.84 3.23-8.35 4.11-11.26 5.29-14.84 5.79-19.01
Power Consumption kW 0.85-3.01 1.28-4.33 1.86-6.06 2.17-7.87 1.28-4.33 1.86-6.06 2.17-7.87 2.37-9.64
Heating Capacity Rated kW 4.41 6.92 10.82 13.77 6.92 10.82 13.77 17.72
COP w/w 2.05 2.02 1.96 1.92 2.02 1.96 1.92 1.99
Heating Capacity A2/W55 kW 2.17-6.63 3.63-9.74 4.62-13.13 5.94-17.30 3.63-9.74 4.62-13.13 5.94-17.30 6.51-22.17
Power Consumption kW 0.78-2.72 1.18-3.91 1.72-5.47 2.00-7.10 1.18-3.91 1.72-5.47 2.00-7.10 2.19-8.70
Heating Capacity Rated kW 5.15 8.07 12.62 16.06 8.07 12.62 16.06 20.67
COP w/w 2.65 2.60 2.53 2.48 2.60 2.53 2.48 2.57
Heating Capacity A7/W55 kW 2.30-7.62 3.85-11.20 4.90-15.10 6.30-19.90 3.85-11.20 4.90-15.10 6.30-19.90 6.90-26.10
Power Consumption kW 0.75-2.61 1.13-3.75 1.65-5.25 1.65-6.82 1.13-3.75 1.65-5.25 1.65-6.82 1.95-8.55
Heating Capacity Rated kW 5.92 9.28 14.51 18.47 9.28 14.51 18.47 23.77
COP w/w 3.17 3.12 3.03 2.97 3.12 3.03 2.97 3.08
Cooling output A35/W7 kW 1.80-7.10 2.60-10.30 4.50-13.50 5.50-17.50 2.60-10.30 4.50-13.50 5.50-17.50 5.20-21.30
Cooling Power Input kW 0.61-2.43 0.91-3.65 1.45-4.85 1.65-6.25 0.91-3.65 1.45-4.85 1.65-6.25 1.95-8.20
Cooling  output Rated kW 5.53 8.54 12.50 15.88 8.54 12.50 15.88 20.44
EER w/w 3.04 3.01 2.77 2.96 3.01 2.77 2.96 2.86
Information of Indoor and Outdoor
Power Input Max. OUT DOOR kW 2.71 3.83 6.2 7.5 3.83 6.2 7.5 10
Current Input Max. A 12 17 27.5 35 6.5 10.5 13 17
Auxiliary heater power IN DOOR kW 3 3 3 3 9 9 9 9
Power Input Max. kW 3.5 3.5 3.5 3.5 9.5 9.5 9.5 9.5
Current Input Max. A 15.6 15.6 15.6 15.6 16.2 16.2 16.2 16.2
Unit Dimensions (W/H/D) OUT DOOR mm 1100×445×850 1100×445×850 1110×480×850 1110×445×1450 1100×445×850 1110×480×850 1110×445×1450 1110×445×1450
Net Weight kg 90 92 109 132 92 109 132 140
Water Piping Connections IN DOOR In G1 G1 G1 G1-1/2 G1 G1 G1-1/2 G1-1/2
Water Pressure Drop kPa 25 27 30 32 27 30 32 35
Water Pressure Min/Max MPa 0.1 / 0.3 0.1 / 0.3 0.1 / 0.3 0.1 / 0.3 0.1 / 0.3 0.1 / 0.3 0.1 / 0.3 0.1 / 0.3
Sound Pressure  level dB(A) 35 35 35 35 35 35 35 35
Unit Dimensions (W/H/D) mm 495×800×280 495×800×280 495×800×280 495×800×280 495×800×280 495×800×280 495×800×280 495×800×280
Net Weight kg 45 48 50 50 48 50 50 50
Main Components
Charged Refrigerant R32 R32 R32 R32 R32 R32 R32 R32
Compressor Type Double-Rotor Double-Rotor Double-Rotor Double-Rotor Double-Rotor Double-Rotor Double-Rotor Double-Rotor
Plate Heat Exchanger Type Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger
Fan Motor Type DC DC DC DC DC DC DC DC
Water Pump Type INVERTER INVERTER INVERTER INVERTER INVERTER INVERTER INVERTER INVERTER

installation diagramof UltraHeat-VISSPLUS R32 split heat pump

ECO-Design Efficiency Level

UltraHeat stands out by its excellent heating performance with precise heating curve design,full INVERTR technology to having quicker heating and stable comfort.It reaches A+++ level at water 35C degree for floor heating and A++ at water 55C degree for the radiators.

A+++ efficiency level of r32 split heat pump (1)
Wide Suitable Climates of heat pump

Wide Suitable Climates

Ultraheat is a split type with a heat pump unit installed outside along side the wall and a refrigerant-water heat transition indoor unit hung on the room wall.They are connected by the copper pipes which are filled with refrigerant,not water.No worry of the freezing pipes.The refrigerant characteristic decide it won’t freeze at a very extremely cold temperature.ULTRAheat compressor has a wide allowable running air temperature down to minus 25degree.

Smart Defrosting and Multi-stages Anti-freezing

Ultraheat heat pump systems can automatically caculate each time for defrosting when it reads diferrent temperature by lots of sensors built-in.Anti-freezing by multipul stages ensure no freezing cracks.

Smart Defrosting and Multi-stages Anti-freezing
Photovaltaic Integration

Photovaltaic Integration

UltraHeat is proved to be a good partner in Green House for getting green heat and gree electricity. UltraHeat reserved the communication port for connection with solar pv electricity.The inserted programming will automatically decides how to let the heat pump runs on different pv status and grid electricity status.

5G/2.4G Compatible WIFI Module+"IOT" Remote Control

Ultraheat allows to be controlled by home owners’ mobile application.

Allows the branders partner after sales technical man and installer to login into the “cloud platform” to check the installed heat pump current status including every water temperature,gas temperature,compressor running hertz,electronic expansion valve open degree…Installers will be authorized by special code to adjust some parameters by himself.Surely the platform will save each notes and diary for each errors for future checking.

5G2.4G Compatible WIFI Module+IOT Remote Control
Reserved RS485 Port Integration Contributing Energy Management

Reserved RS485 Port Integration Contributing "Energy Management"

It is an amazing function for some branders who have the ambitions to integrate a complex “Energy Management Platform” which groups lots of appliances concerning about photovaltaic,charging,heat pump,energy meters.It benefits the home owner that they don’t need to reach the heat pump controller ofen which is far away from normal living space.In a energy management platform,home owner can know everything about her heat pump.

 

 

Send Your Inquiry Today
Quick Quote
Scroll to Top