x
Send Your Inquiry Today
Quick Quote
Air to water heat pump units for differen buildings
  • Westeros Residetial R290 air to water heat pump 6kw 8kw 10kw 12kw 16kw 18kw
  • Westeros Residetial R290 air to water heat pump 18kw triple phase
  • Westeros Residetial R290 air to water heat pump 10kw 12kw 16kw
  • Westeros Residetial R290 air to water heat pump 6kw 8kw
  • Westeros Residetial R290 air to water heat pump 6kw 8kw 10kw 12kw 16kw 18kw
  • Westeros Residetial R290 air to water heat pump 18kw triple phase
  • Westeros Residetial R290 air to water heat pump 10kw 12kw 16kw
  • Westeros Residetial R290 air to water heat pump 6kw 8kw

Westeros Residential Series
Monoblock Air to Water Heat Pump filled with R290 refrigerant

Refrigerant: R290
Power: Single and Triple Phase
Type of Components Full DC Inverter
Capacity Availability: 6-18kw
ErP Class: A+++(35°C),A+++(35°C)
Max.Water Temperature: 75°C
Type All in one  Monoblock
Operating Temperature: -28~48°C

Description and Applications of Westeros

Westeros Series is developed by VISSPLUS,a heat pump manufacturer.Its concept is a compact structure which consists of refrigeration circulation part,and also the gas-water heat transition circuit ,also the water pressure initial balancing system is included.So it consist of compressor,fan motor,various valves,and plate heat exchanger,water circulation pump(to the buffer tank),electric heater for backup and balancing vessel.The whole system is monitored by various sensors and transducers connected to the brain of the heat pump-electronic boards.

Westeros produce hot water flow to the radiators and underfloor-loops for warming the room air and fan coil to blow wam and cool air both.

heating and cooling and hot water funciton of Westeros heat pump

R290 DHW Heat Pump Collections

6kw single phase 220V R290 Air to Water heat pump-vissplus westeros residential
  • Mono Power Phase
  • 6kW Rated Heating Capacity(A7C/W35C)
  • R290 Filled Refrigerant
  • A+++/A+++
8kw single phase 220V R290 Air to Water heat pump-vissplus westeros residential
  • Mono Power Phase
  • 8kW Rated Heating Capacity(A7C/W35C)
  • R290 Filled Refrigerant
  • A+++/A+++
12kw single phase 220V R290 Air to Water heat pump-vissplus westeros residential
  • Mono Power Phase
  • 12kW Rated Heating Capacity(A7C/W35C)
  • R290 Filled Refrigerant
  • A+++/A+++
12kw triple phase 380V R290 Air to Water heat pump-vissplus westeros residential
  • Triple Power Phase
  • 12kW Rated Heating Capacity(A7C/W35C)
  • R290 Filled Refrigerant
  • A+++/A+++
16kw single phase 220V R290 Air to Water heat pump-vissplus westeros residential
  • Single Power Phase
  • 16kW Rated Heating Capacity(A7C/W35C)
  • R290 Filled Refrigerant
  • A+++/A++
16kw triple phase 380V R290 Air to Water heat pump-vissplus westeros residential
  • Triple Power Phase
  • 16kW Rated Heating Capacity(A7C/W35C)
  • R290 Filled Refrigerant
  • A+++/A++
18kw triple phase 380V R290 Air to Water heat pump-vissplus westeros residential
  • Triple Power Phase
  • 18kW Rated Heating Capacity(A7C/W35C)
  • R290 Filled Refrigerant
  • A+++/A+++
Westeros Residential R290 Air to Water Monoblock Heat Pump
Capacity 6kW 8kW 12kW 12kW 16kW 16kW 18kW
Factory Models VR1HM-060INV VR1HM-080INV VR1HM-120INV VR1HM-120INV-T VR1HM-160INV VR1HM-160INV-T VR1HM-180INV-T
Max. outlet water Temp. °C 75
PERFORMANCE
Power Supply 220 ~ 240V ~ /50Hz 220 ~ 240V ~ /50Hz 220-240 ~ / 50Hz 380 ~ 415V/3N ~ /50Hz 220-240V ~ / 50Hz 380 ~ 415V/3N ~ /50Hz 380 ~ 415V / 3N / 50Hz
*Heating Condition A7/6℃,W30/35 (Nominal & Min ~ Max)
Heating Capacity kW 6.07 (2.63 ~ 9.10) 8.11 (3.57 ~ 12.29) 11.98 (4.39 ~ 15.45) 11.98 (4.39 ~ 15.45) 16.20 (6.17 ~ 18.51) 16.20 (6.17 ~ 18.51) 17.60 (6.50 ~ 22.00)
Power Input kW 1.19 (0.54 ~ 2.28) 1.60 (0.74 ~ 3.17) 2.45 (0.89 ~ 4.06) 2.45 (0.89 ~ 4.06) 3.38 (1.26 ~ 4.83) 3.38 (1.26 ~ 4.83) 3.62 (1.35 ~ 5.88)
COP / 5.10 (4.20 ~ 5.40) 5.07 (4.10 ~ 5.35) 4.89 (3.85 ~ 5.20) 4.89 (3.85 ~ 5.20) 4.79 (3.75 ~ 5.00) 4.79 (3.75 ~ 5.00) 4.86 (3.82 ~ 5.30)
*Heating Condition A7/6℃,W47/55 (Nominal & Min ~ Max)
Heating Capacity kW 5.99 (2.99 ~ 8.19) 8.11 (3.65 ~ 10.96) 11.55 (3.85 ~ 13.35) 11.55 (3.85 ~ 13.35) 15.89 (5.75 ~ 17.20) 15.89 (5.75 ~ 17.20) 17.85 (5.45 ~ 18.89)
Power Input kW 1.87 (1.03 ~ 2.92) 2.65 (1.11 ~ 3.87) 3.71 (1.20 ~ 5.03) 3.71 (1.20 ~ 5.03) 5.30 (1.81 ~ 5.84) 5.30 (1.81 ~ 5.84) 5.88 (2.15 ~ 6.85)
COP / 3.20 (2.90 ~ 3.46) 3.18 (2.83 ~ 3.45) 3.11 (2.65 ~ 3.57) 3.11 (2.65 ~ 3.57) 3.00 (2.83 ~ 3.45) 3.00 (2.83 ~ 3.45) 3.03 (2.64 ~ 3.57)
*Cooling Condition A35/24℃,W12/7 (Nominal & Min ~ Max)
Cooling Capacity kW 5.00 (1.38 ~ 5.70) 7.10 (1.44 ~ 8.11) 10.00 (3.65 ~ 11.04) 10.00 (3.65 ~ 11.04) 13.00 (4.03 ~ 13.51) 13.00 (4.03 ~ 13.51) 15.00 (4.55 ~ 17.20)
Power Input kW 1.77 (0.67 ~ 2.44) 2.51 (0.90 ~ 3.20) 3.68 (1.12 ~ 3.97) 3.68 (1.12 ~ 3.97) 4.60 (1.45 ~ 5.03) 4.60 (1.45 ~ 5.03) 5.52 (1.85 ~ 7.31)
EER / 2.82 (2.03 ~ 3.20) 2.83 (2.00 ~ 3.15) 2.72 (1.95 ~ 3.00) 2.72 (1.95 ~ 3.00) 2.83 (1.98 ~ 3.05) 2.83 (1.98 ~ 3.05) 2.72 (1.96 ~ 2.98)
ERP Level (Outlet water temp. at 35℃/55℃) / A+++/A+++ A+++/A++ A+++/A+++
Operating temperature range (Heating mode) °C -25 ~ 45
Operating temperature range (Cooing mode) °C 16 ~ 45
Rated Power Input kW 3.6 4.65 5.45 5.86 6.95 6.95 10.52
Rated Current Input A 15.0 20.4 25.0 10.5 30.5 11.7 17.3
Refrigerant Type / Charge / GWP … / kg R290 / 0.85 / 3 R290 / 0.90 / 3 R290 / 1.00 / 3 R290 / 1.00 /3 R290 / 1.15 /3 R290 / 1.15 /3 R290 / 1.4 / 3
Rated water flow m³/h 1.00 1.37 2.06 2.06 2.75 2.75 3.1
Water Pressure Drop kPa 20 25 55
*Sound pressure at 1m distance dB (A) 43 (39 ~ 51) 43 (39 ~ 51) 46 (39 ~ 52) 46 (39 ~ 52) 48 (39 ~ 55) 48 (39 ~ 55) 49 (39 ~ 55)
*Sound pressure at 3m distance dB (A) 35 (32 ~ 44) 35 (32 ~ 44) 39 (32 ~ 45) 39 (32 ~ 45) 41 (32 ~ 48) 41 (32 ~ 48) 47 (32 ~ 48)
COMPONENTS
Fan quantity / 1
Fan motor type / DC inverter
Compressor / DC inverter
Circulating pump / Inverter type / Built-in
INSTALLATION
IP Class / IPX4
Water Piping Connections inch G1
UnPacked Weight kg 140 145 195
Packed Weight kg 160 165 220
Unpacked Dimensions ( L×W×H ) mm 1270*460*955 1490*500*1005
Packed Dimensions ( L×W×H ) mm 1300*500*1090 1520*540*1140
*Nominal data is based on tests conducted in accordance with EN14511. Performance range (in brackets) is declared according to minimum and maximum power.
Note: The data above is for reference only. Please refer to the nameplate on the unit if for more specific data.

R290 New Refrigerant

Being a natural refrigerant, R290 is more sustainable and less harmful to the environment than synthetic refrigerants. Its use aligns with global efforts to reduce greenhouse gas emissions.Filled with R290 refrigerant,Westeros have better heat transfer leading to better Performance at Low Temperatures.Moreover,R290 require less filled amount.

R290 refrigerant of VISSPLUS domestic hot water heat pump 2 副本 (1)
75C of r290 heat pump -vissplus

Higher Water Temperature up to 75°C

Besides the selection by newly-construction houses to have GREEN houses ,but also Westeros is a perferct choice for old house heating system renovation.The home owner won’t have the headache of changing to whole heating system including old radiators and old pipes.He can keep them and connect to the Westeros heat pump.Old radiators require higher water temperature to keep the room warm.

5X Higher COP

Basically WESTEROS reaches the European ECODESIGN heat pump efficiency level by A+++ at 35degrees and A++ at 55degrees water temperature.WESTEROS is not just meet the bottom line,It is higher than the standard

high cop of westeros of r290 heat pump
lower noise level of r290 heat pump

"Bee Quiet"

Noise is usually the 1st headache which the end user found easily. WESTEROS developed “Bee Quiet” tech to improve the internal design,air flow directions,compressor frequency adjustment,fan motor speed auto-adjustment.Surely a silent heat pump installation is also related with the whole house system design/installation/commissioning.

Multi-Temperature Curves Table

WESTEROS is capable to adjust the leaving water temperature by the outdoor air temperature automatically.Users don’t need to adjust it by hand.Especially in some area and seasons,when the day and night temperature gap is big,It is very useful to get a faster and comfort room temperature.

multi-curve of r290 heat pump
5G2.4G Compatible WIFI Module+IOT Remote Control

WIFI App both for 5G/2.4G +"IOT" Remote Control

Mobile Application control is standard delivery for WESTEROS.WESTEROS also offer the option of “IoT” solution.Which the customers and installers can access to check all his belongings heat pumps every thing.

Availability of RS485 Port Integration with Your "Energy Management"

WESTEROS have the RS485 port reserved in the heat pump and it is cooperative for VISSPLUS manufacturer to offer the technical protocol data for customers to build your own energy management.

Reserved RS485 Port Integration Contributing Energy Management

Special Features and buying Points:

  • The gas leakage sensor is standard in the heat pump.It functions to cut off the electricity when there is centage of gas leakge
  • The vapor valve can be optional in the heat pump to let the gas blow out when there is gas leakage into the water

  • the compressor is completely sealed in a metal box with higher thick foam on the back of metal,which can reduce the noise
  • Optional Remote control /IOT/OTA function:through this platform,customers/installers can view ,revise the heat pump status and change the parameter..etc 。Cost saved

  • Energy consumption reading function:through the Controller interface and IOT platform,the electricity consumption can be read easily

heat pump dimension of westeros
heat pump dimension of westeros
Wired Controller Interface of R290 heat pump westeros
Wired Controller Interface of R290 heat pump westeros
Energy label of Air to water heat pump R290
Energy label of Air to water heat pump R290
Send Your Inquiry Today
Quick Quote
Scroll to Top